Environmental Testing

Climatic Test Chamber with Vibration

  • OEM NAME : AKI India
  • Specification/Capacity : Temp range: -60°C to +180°C
    Humidity: 20% to 95%
    Work space: 1200 mm (W) X 1200 mm (D) X 2000 mm (H)
  • Application : To carry out steady state as well as cyclic temperature and humidity tests with Vibration
Enquire Now

Salt Spray Test/corrosion Test Chamber

  • OEM NAME : AKI India
  • Specification/Capacity : Temp range: 10°C above ambient to 70°C
    Humidity: 95% to 100% during high humidity
    Work space: 1500mm(W) × 800mm(D) × 800mm(H)
  • Application : To check corrosion resistance of ferrous, non-ferrous, organic, and non-organic coatings
Enquire Now

Thermal Shock Test

  • OEM NAME : AKI India
  • Specification/Capacity : Hot zone: 10°C above ambient to +150°C  ±1°C 
    Cold Zone: -50°C to +70°C  ±1°C
    Work space: 560mm(W) × 600mm(D) × 600mm(H)
    Basket transfer time: Less than 10 sec.
    FOG collection rate: Between 0.5 to 2.0 ml/hr.
  • Application : Thermal Shock is performed to determine the resistance of the part to sudden changes in temperature
Enquire Now

Dust Chamber Test

  • OEM NAME : AKI India
  • Specification/Capacity : Temp range: 10°C above ambient to +70°C ±1°C
    Work space: 1000mm(W) × 1000mm(D) × 2000mm(H)
    IP5X and IP6X
  • Application : For protection of the equipment inside the enclosure against harmful effects due to ingress of solid foreign particles.
Enquire Now

Rain Test/Water Spray Chamber

  • OEM NAME : AKI India
  • Specification/Capacity : 1.Work space:
    a) For IEC/JSS Standard 500mm(W) × 250mm(D) × 470mm(H)
    b) For IS Standard 500mm(W) × 500mm(D) × 1500mm(H),
    IPX3
  • Application : For protection of the equipment inside the enclosure against harmful effects due to ingress of water
Enquire Now

Vibration shaker

  • OEM NAME : Spectral dynamics
  • Specification/Capacity :
    1. Generated Force: a) Sine (Pk)= 1100kgf, b) Random (Rms)= 1100 kgf, c) Shock (Pk)= 2200 kgf
    2. Resonance Frequency= 2614 Hz.
    3. Sleep table natural frequency= 1350 Hz.
    4. Maximum displacement (Peak-Peak)= 51mm
    6. Maximum Acceleration= 100g
    7. Maximum size of EUT/ Fixture for Vertical Test= (M8, 100 mm pitch)700 mm× 700mm
    8. Maximum size of EUT/ Fixture for Horizontal Test= (M8, 100 mm pitch)800 mm× 800mm
    9. X-Y-Z Direction.
  • Application : To verify functional and structural integrity of EUT during and after vibration test events.
Enquire Now